KTI Networks KSD-800M Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Switche sieciowe KTI Networks KSD-800M. KTI Networks KSD-800M User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 65
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
-1-
DOC.050710
KSD-800M
Series
Industrial Managed 8-Port Fast Ethernet Switches
with Fiber Connectivity
Installation Guide
Przeglądanie stron 0
1 2 3 4 5 6 ... 64 65

Podsumowanie treści

Strona 1 - KSD-800M

-1-DOC.050710KSD-800MSeriesIndustrial Managed 8-Port Fast Ethernet Switcheswith Fiber ConnectivityInstallation Guide

Strona 2

-10-Model 800M-1 series provide eight 10/100TX copper ports and one 100FX fiber connector. Port 8supports dual network cable types.Model 800M-2 series

Strona 3

-11-1.6 Top PanelAll three model series provide same top panel as figure shown below:The main functions are:DC Power Jack This connector is used when

Strona 4 - Table of Contents

-12-10/100TX Twisted Pair PortsCompliance IEEE 802.3 10BASE-T, IEEE 802.3u 100BASE-TXConnectors Shielded RJ-45 jacksPin assignments Auto MDI/MDI-X det

Strona 5

-13-Software Management FunctionsInterfaces Web, telnet, SNMP MIB-II & private MIB, TrapsManagement objects Port configuration control and statusU

Strona 6 - 1. Introduction

-14-DC Power InputInterfaces Euro type terminal block contacts(DC1 DC2 : 2 sets for power wire cascading)DC Jack ( -D 6.3mm / + D 2.0mm)Operating Inpu

Strona 7 - 1.1 Features

-15-Optical SpecificationsA variety of fiber options and the optical specifications is provided as follows:Model FX Port & Cable Wavelength Tx Pow

Strona 8 - 1.2 Product Panels

-16-2. Installation2.1 UnpackingThe product package contains:• The switch unit• One DIN-rail mounting kit• One product CD-ROM2.2 Safety CautionsTo

Strona 9 - 1.4 Network Ports

-17-2.3 DIN-Rail MountingIn the product package, a DIN-rail bracket is provided for mounting the switch in a industrial DIN-railenclosure.The steps t

Strona 10 - 1.5 LED Indicators

-18-2.4 Panel MountingThe switches are provided with an optional panel mounting bracket. The bracket support mounting theswitch on a plane surface se

Strona 11 - 1.7 Specifications

-19-3. Screw the switch unit on a panel. Three screw locations are shown below:

Strona 12

-2-(C) 2002 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced inany form or by any means or used to make any dire

Strona 13

-20-2.5 Applying PowerThe power specifications of the switch are:Operating Voltage +7 ~ +30VDCPower Consumption Max. 8.3W @30VDCThe switch provides t

Strona 14 - 1.8 Model Definitions

-21-Using DC Power JackWhen an external power system is not available, the switch provides a DC jack to receive power fromtypical AC-DC power adapter

Strona 15 - Optical Specifications

-22-2.7 Reset ButtonThe reset button is used to perform a reset to the switch. It is not used in normal cases and can be usedfor diagnostic purpose.

Strona 16 - 2. Installation

-23-2.9 Making Fiber ConnectionsFX7 port and FX8 port operate on 100Mbps and full duplex.The following figure illustrates a connection example betwee

Strona 17 - 2.3 DIN-Rail Mounting

-24-2.10 LED IndicationLED Function State InterpretationPWR Power status ON The power is supplied to the switch.OFF The power is not supplied to the

Strona 18 - 2.4 Panel Mounting

-25-2.11 Configuring IP Address for the SwitchThe switch is shipped with the following factory default settings for software management :Default IP ad

Strona 19

-26-3. Advanced FunctionsTo help a better understanding about the software management interfaces, this chapter describes someadvanced functions provid

Strona 20 - 2.5 Applying Power

-27-3.1.3.1 Port-based Priority Setting (per port setting)As one port is configured to be enabled for port-based priority, all received packets on the

Strona 21

-28-3.1.3.4 IP Network Address ClassificationUser can configured two IP network address settings, IP(A) and IP(B). If a received IP packet’ssource add

Strona 22 - 2.8 Making UTP Connections

-29-3.2 VLAN FunctionThe switch supports port-based VLAN, 802.1Q Tag Aware VLAN and eight VLAN groups. SomeVLAN related terminologies are described as

Strona 23 - 2.9 Making Fiber Connections

-3-The information contained in this document is subject to change without prior notice. Copyright (C). AllRights Reserved.TRADEMARKSEthernet is a reg

Strona 24 - 2.10 LED Indication

-30-The following sections describe the VLAN processes and related settings provided by the switch. Aglobal setting means the setting is applied to al

Strona 25 - • Password : 123

-31-3.2.3 VLAN Group MappingThe VLAN group mapping is the switch’s decision process to find a right VLAN group for the re-ceived packet when it is not

Strona 26 - 3. Advanced Functions

-32-3.2.5.2 Null VID Replacement (per port setting)The null VID of a Null VID packet will be replaced with the associated ingress port’s PVID. Thisset

Strona 27

-33-4. Software ManagementThe switch provides the following in-band management interfaces for configuring the switch to meetrequirements for different

Strona 28 - 3.1.4 Other QoS Settings

-34-4.2 IP MenuSelect [1] IP Menu to configure IP protocol related settings for the switch.IP Menu:[0] Print this menu[1] Set IP Address[2] View IP st

Strona 29 - 3.2.1 VLAN Operation

-35-4.3 SNMP MenuThis menu is used for configuring SNMP protocol related settings.Snmp Menu:[0] Print this menu[1] View Snmp Setting[2] Set Snmp Name[

Strona 30 - 3.2.2 Ingress Rules

-36-4.4 Port ConfigSelect [3] Port Config to configure port configuration.Port Config Menu:[0] Print this menu[1] Port Status[2] Port Config[Q] Back M

Strona 31 - 3.2.5 Egress Tagging Rules

-37-Speed Control Speed configuration when auto-negotiation is disabled100M - 100Mbps10M - 10MbpsDuplex Control Duplex configuration when auto-negotia

Strona 32

-38-Select [1] VLAN Group Information to view all groups.VLAN Select: Disable VLANMember Ports (O : member, - : not member): G\P 1 2 3 4 5

Strona 33 - 4. Software Management

-39-VLAN Global Settings Description802.1Q Tag Aware Mode Enable - Under this mode, the switch will check the content ofevery received packets. For 80

Strona 34 - 4.2 IP Menu

-4-Table of Contents1. Introduction... 61.1 Features

Strona 35 - 4.3 SNMP Menu

-40-Select [6] VLAN Per Port Settings to configure VLAN ID for VLAN groups.VLAN Per Port Settings: Port Default Unmatched Egress Null No. Gro

Strona 36 - 4.4 Port Config

-41-Null VID The null VID of a Null VID packet will be replaced with the associatedingress port’s PVID. This setting still works even Egress Tag rule

Strona 37 - 4.5 Administrator

-42-Default TOS/DS classification Enable - If the packets DSCP value is one the default code pointlisted below, the packet is classified as high prior

Strona 38

-43-Select [2] - [5] to configure other settings as follows:QoS Other Settings Description802.1p priority tag 802.1p High Priority Tag Threshold Setti

Strona 39

-44-4.6 Restore Default ValuesSelect [6] Restore Default Values to restore all settings of the switch back to factory default values.Do you want to re

Strona 40

-45-4.8 Update FirmwareSelect [7] Update Firmware to update the firmware of the switch. A new firmware may be releasedby the factory due to function e

Strona 41

-46-5. Web ManagementThe switch features an http server which can serve the management requests coming from any webbrowser software over internet or i

Strona 42

-47-The following screen shows welcome screen when a successful login is performed.In addition to the device image, the screen supports the following

Strona 43

-48-5.3 Port Status MenuClick >Port Status Menu to display the port status for all switched ports. The pop-up port status list isas follows:Port St

Strona 44 - 4.7 Security Manager

-49-5.4 AdministratorClick >Administrator to perform more advanced management functions as follows:Menu FunctionBasic Configure IP and SNMP setting

Strona 45 - 4.10 Exit

-5-3.2.2.3 Unmatched VID Filtering (per port setting) ...303.2.3 VLAN Group Mapping ...

Strona 46 - 5. Web Management

-50-IP AddressIP Address Setting DescriptionIP Address IP address for the switchSubmask Subnet mask of the IP addressGateway IP address of the default

Strona 47

-51-Community Settings DescriptionCommunity String Community strings which are allowed to access the switch unit via SNMPprotocolAccess Right The acce

Strona 48 - 5.3 Port Status Menu

-52-Trap Manager Settings DescriptionIP Address Specify the IP address of the trap manager to which the switch willsend Snmp traps when predefined eve

Strona 49 - 5.4.1 Basic Menu

-53-Speed Control Select port speed when auto-negotiation is disabled, options:Null - unchanged100M - 100Mbps10M - 10MbpsDuplex Control Select port du

Strona 50

-54-Global Settings DescriptionVLANVLAN Select Enable VLAN - Enable switch VLAN functionDisable VLAN - disable switch VLAN functionIngress Rules802.1Q

Strona 51

-55-Group Settings DescriptionGroups Specify the VLAN group for member port configurationPort Specify the port to be added into or deleted from the sp

Strona 52 - 5.4.2 Port Controls

-56-Per Port Settings

Strona 53 - 5.4.3 VLAN Controls

-57-Per Port Settings DescriptionPort Select port list for configuration.Ingress RulesDefault Group Index to the default VLAN group of the selected po

Strona 54

-58-5.4.4 QoS ControlsQoS settings are divided into two categories:1. Per Port Settings - QoS settings for each port2. Other Settings - Some global Qo

Strona 55

-59-QoS Global Settings Description802.1p high priority threshold 802.1p High Priority Tag Setting for 802.1p classificationValid values : 0 - 7Egress

Strona 56 - Per Port Settings

-6-1. IntroductionThe KSD-800M series are managed 8-port full wire speed Fast Ethernet switches for industrial appli-cations. Depending on the fiber

Strona 57

-60-IP(A) address and IP(A) subnet mask specify IP(A) user definedIP network address for IP packet classification.Specific IP & Mask (B) If a rece

Strona 58 - 5.4.4 QoS Controls

-61-5.4.5 Security ManagerThis menu is used to change the user name and password. User name and password are used foraccess login in telnet and web ma

Strona 59

-62-5.4.7 Update FirmwareThis menu is used to perform firmware (switch software) upgrade via TFTP protocol. Before doingTFTP operation, one TFTP serve

Strona 60

-63-6. SNMP ManagementThe switch supports SNMP v1 protocol for SNMP management. One device MIB file is provided inthe product CD. The MIB file is used

Strona 61 - 5.4.6 Image Refresh Time

-64-Appendix. Factory Default SettingsIP SettingsIP Address 192.168.0.2IP Subnet mask 255.255.255.0Gateway IP 192.168.0.1Security Manager SettingsUser

Strona 62 - 5.4.9 Reboot System

-65-VLAN group 5 member : P5, VID : 5VLAN group 6 member : P6, VID : 6VLAN group 7 member : P7, VID : 7VLAN group 8 member : P8, VID : 8Default VLAN g

Strona 63 - 6. SNMP Management

-7-Designed for Industrial ApplicationsFor industrial environment, the switches are designed with the following enhanced features:n High and wide oper

Strona 64

-8-1.2 Product PanelsThe following figure illustrates three major panels of model 800-2 series as example:

Strona 65

-9-1.3 Front PanelThe figure below shows the individual front panel of three model series. The main difference is thenumber of the equipped fiber por

Komentarze do niniejszej Instrukcji

Brak uwag